This trade off can be derived analytically using the Cramer-Rao t

This trade off can be derived analytically using the Cramer-Rao type bounds, which imply the calculation and the inversion of the Fisher information matrix (FIM). The inverse of the FIM expresses the uncertainty associated to the tomogram, enabling the

comparison of system designs. However, computing, storing and inverting the FIM is not practical with 3-D imaging systems. In order to tackle the problem of the computational load in calculating the inverse of the FIM, a method based on the calculation https://www.selleckchem.com/products/MGCD0103(Mocetinostat).html of the local impulse response and the variance, in a single point, from a single row of the FIM, has been previously proposed for system design. However this approximation (circulant approximation) does not capture the global interdependence between the variables in shift-variant systems such as SPECT, and cannot account e. g., for data truncation or missing data. Our new formulation relies on subsampling the FIM. The FIM is calculated over a subset of voxels arranged in a grid that covers the whole volume. Every element of the FIM at the grid points is calculated exactly, accounting for the acquisition geometry and for the object. This new formulation reduces the computational complexity in estimating

the uncertainty, but nevertheless accounts for the global interdependence between the variables, enabling the exploration of design spaces hindered by the circulant approximation.

The graphics processing unit accelerated implementation selleck inhibitor of the algorithm reduces further the computation times, making the algorithm a good candidate for real-time optimization of adaptive imaging systems. This paper describes the subsampled FIM formulation and implementation details. The advantages and limitations of the new approximation are explored, in comparison with the circulant approximation, in the context of design optimization of a parallel-hole collimator SPECT system and of an adaptive imaging system (similar to the commercially available D-SPECT).”
“Objective. Determine if the multidimensional pain-related experience differs between cognitively intact and impaired older adults.

Design. Cross-sectional analysis of the Canadian Study of Health and Aging.

Setting. selleck kinase inhibitor Community-dwelling older adults.

Outcome Measures. Pain reports were dichotomized from a 5-point scale into no/very mild vs moderate and greater. Cognition measured by the Modified Mini Mental State Exam (0-100) was dichotomized into cognitively intact (>77) and cognitively impaired (<= 77). Five self-rated Instrumental Activities of Daily Living (IADL) were dichotomized into no impairment vs any impairment. The Mental Health Inventory consists of five self-rated questions about psychological state and well-being, with scores ranging from 0 to 30; scores >11 indicate depression.

Comments are closed.