Results: Masticatory efficiency at 5 months was significantly imp

Results: Masticatory efficiency at 5 months was significantly improved for the 0.42-mm PARP activation mesh.

An improvement in masticatory efficiency and a reduction in mastication time were observed with the new dentures after 1 year. Conclusion: The results of this study indicated that 5 months did not allow enough time to demonstrate improved muscular capacity and ability after receiving new dentures. After 1 year, the duration of the masticatory cycle was reduced, and masticatory efficiency was significantly improved. “
“This clinical report describes a technique to stabilize a computer-aided dental implant surgical guide to existing implants. A patient requested conversion of her existing mandibular implant-assisted overdenture into a fixed complete denture. The surgical procedure was planned virtually, and the two existing dental DNA Damage inhibitor implants were integrated into the surgical plan as a means to fixate the surgical guide. The implants were placed, and the patient’s prosthesis was converted into an interim

fixed complete denture. “
“Purpose: The purpose of this study was to examine the fracture load of ceramic veneers with different preparation designs. Materials and Methods: Seventy-five extracted, intact, human maxillary central incisors were prepared according to five preparation designs (P) (n: 15) as follows: (1) P2e: 2-mm incisal reduction, preparation entirely in enamel; (2) P4e: 4-mm incisal reduction, preparation entirely in enamel; (3) P2d: 2-mm incisal reduction, preparation entirely in dentin; (4) P4d: 4-mm incisal reduction, preparation entirely in dentin; and (6) Pc: Unrestored, intact teeth as control. All preparations had a butt joint incisal finish line, rounded internal line angles, and cervical finish lines 1 mm above the cementoenamel junction. Ceramic veneers were fabricated with IPS Empress (Ivoclar Vivadent AG, Schaan, Liechtenstein) and cemented with Syntac Classic Adhesive system and Variolink II (Ivoclar)

resin cement. Veneers were loaded until fracture at a 90° angle to the lingual Quinapyramine surface of the test tooth following the thermocycling process (5° to 55°, 3500 times). Statistical analyses were performed using analysis of variance (ANOVA) and Tukey’s Multiple Range Test. Results: The mean fracture loads (SD) were (in N) as follows: (1) P2e: 262 (63); (2) P4e: 189 (40); (3) P2d: 239 (53); (4) P4d: 162 (36); and (5) Pc: 277 (66). The amount of incisal reduction exhibited a significant influence on fracture resistance regardless of the preparation depth (p < 0.05). Conclusions: Ceramic veneers with preparation designs entirely on dentin with 4-mm incisal reduction yielded lower fracture loads than those prepared with 2-mm incisal reduction. Veneers with 2-mm incisal reduction exhibited fracture resistance similar to that of intact teeth for preparation designs supplied on both enamel and dentin.

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>